Reactive Power Compensation and Power Quality Management Device
General
The APF features a modular design with compact size and lightweight construction, enabling installation without requiring cranes or forklifts, thereby saving time and labor. Its wall-mounted design offers flexible installation, making it particularly suitable for space-constrained locations.
The APF provides multiple monitoring options tailored to different models, including:
-
3.8-inch LCD display
-
4.3-inch color touchscreen
-
8-inch full-color LCD touchscreen
-
Background monitoring software
This versatility ensures adaptability to diverse user requirements.

General
The ASVG continuously monitors load current through external current transformers (CTs). Its internal DSP calculates and extracts the reactive and harmonic components from the load current. Subsequently, it generates PFM signals to control the IGBT inverter, producing precise reactive current and low-order harmonic currents as configured. This achieves combined reactive power compensation and harmonic mitigation.

General
The ASVG utilizes external current transformers (CT) to monitor load current in real-time. The internal DSP calculates and extracts the reactive power components and harmonics from the measured load current. It then sends PFM signals to control the IGBT-based inverter, which generates the required reactive current and low-order harmonic currents according to preset parameters. This achieves simultaneous reactive power compensation and harmonic suppression.

Technical Specifications
-
Multiple Compensation Modes (Harmonics, Reactive Power, Three-Phase Imbalance, Capacitor Switching Control): Simultaneously perform all four types of compensation.
-
Capable of Filtering 2nd to 50th Harmonics within Rated Capacity: Effectively removes a wide range of harmonics from the power system.
-
Power Factor Above 0.98 After Compensation at Rated Capacity: Ensures high efficiency and reduced energy losses in the electrical system.
-
Three-Phase Active Current Imbalance Less Than 5% After Compensation at Rated Capacity: Maintains balanced load distribution across all three phases.
-
Automatic Current Limiting Function to Prevent Overload: Safeguards against excessive current draw, enhancing system reliability.
-
Fast Response and High Controllability with Tracking of All Harmonics and Dynamic Generation of Required Harmonic Currents for Load Changes: Quickly adapts to changing conditions, ensuring continuous harmonic mitigation and efficient load management.
-
Standard Communication Interfaces Including Bluetooth, RS-485 Bus Communication, and Optional GPRS Module for Remote Data Monitoring: Enables seamless integration with monitoring systems and allows for remote diagnostics and data retrieval.
These features ensure comprehensive performance in improving power quality and system efficiency.