Others
Summary
Enclosed busbar is an electrical power transmission system designed to safely and efficiently carry high currents in industrial, commercial, and infrastructure applications. It consists of a metallic enclosure (e.g., steel, aluminum, or fire-resistant panels), conductive bars (copper, aluminum, or copper-aluminum composites), insulating materials, and supporting components. It is widely used in power generation, transformation, and distribution systems.
Structural Characteristics
- The aluminum-magnesium alloy enclosure is lighter, with better sealing and heat dissipation. Its special structure has sufficient mechanical strength to support and protect the bus duct system.
- The "connection set type" method is more convenient.
- Specialized connectors make the bus connection simpler and the installation faster.
- High-grade insulation materials - safer.
- The conductor surface has a multi-layer Class B (130°C) polymer film with a thickness of up to 0.5mm.
- The contact parts of the bus conductor are tin-plated, which improves contact resistance and prevents electrochemical corrosion.
- The enclosure (excluding the heat dissipation holes) can provide a protection rating of IP40 to IP65 or higher.
Standards Compliant
- GB 7251.2-2006 "Low-voltage switchgear and controlgear assemblies" Part II: Special requirements for busbar trunking systems (bus ducts);
- GB 7251.2-2005 "Low-voltage switchgear and controlgear assemblies" Part I: Type testing and partial type testing;
- JB/T 9662-1999 "Dense insulation busbar trunking systems (dense insulation bus ducts)";
- GB 4208-1993 "Ingress protection (IP code)";
- GB/T 5585.2-2005 "Copper, aluminum and their alloys for electrical purposes - Part 1: General specifications";
Technical Parameter
- Rated voltage: AC 660V, rated current: 400A~5000A, rated frequency: 50Hz;
- Power frequency withstand voltage: 3500V, heat resistance class: B, insulation class: B;
- Busbar system: TN-S, three-phase five-wire system;
- Busbar structure: Dense type (including plug-in sections);
- Protection level IP54;
- Plug-in box connection device: Silver-plated contact pins, can be plugged and unplugged more than 200 times, good interchangeability of sockets and meets temperature rise requirements;
- Conductor busbar temperature rise: The temperature rise of the conductor at the main busbar or busbar connector, and at the plug-in box claws and busbar connection points, does not exceed 70℃;
Application
- Indoor ambient air temperature: -15~+40℃;
- Indoor usage altitude: ≤2000m;
- Ambient air relative humidity ≤90% (at +25℃);
- Environmental pollution degree: Level II;
- Seismic intensity not exceeding 8°, and no severe vibration areas;